{"id":3603,"date":"2026-06-18T13:39:26","date_gmt":"2026-06-18T05:39:26","guid":{"rendered":"https:\/\/sinocleansky.com\/product\/en-iso9809-cylinder-tped\/"},"modified":"2026-07-27T18:13:34","modified_gmt":"2026-07-27T10:13:34","slug":"en-iso9809-cylinder-tped","status":"publish","type":"product","link":"https:\/\/www.sinocleansky.com\/pt\/product\/en-iso9809-cylinder-tped\/","title":{"rendered":"Cilindro EN ISO 9809 (TPED)"},"content":{"rendered":"<p>As garrafas de g\u00e1s SinoCleansky EN ISO 9809 s\u00e3o fabricadas em estrita conformidade com a norma EN ISO 9809, possuem aprova\u00e7\u00e3o TPED e apresentam a marca \u03c0 na garrafa. As garrafas s\u00e3o acompanhadas de relat\u00f3rios de ensaio de terceiros da TUV International. Sendo um produto de gama alta, este tipo de garrafa \u00e9 amplamente utilizado no mercado europeu e cumpre requisitos mais exigentes.<br \/>\nOs cilindros s\u00e3o amplamente utilizados para oxig\u00e9nio (O\u2082), azoto (N\u2082), \u00e1rgon (Ar), di\u00f3xido de carbono (CO\u2082), h\u00e9lio (He), \u00f3xido nitroso (N\u2082O), hidrog\u00e9nio (H\u2082) e outros, abrangendo os setores industrial, de combate a inc\u00eandios, energ\u00e9tico, m\u00e9dico, de constru\u00e7\u00e3o urbana e outros.<br \/>\nE os cilindros incluem os cilindros fabricados por laminagem, bem como os cilindros perfurados a partir de um bloco de metal.<\/p>\n<p><strong>Cilindro popular EN ISO 9809 (TPED)<\/strong><strong><\/strong><\/p>\n<p>Todos os cilindros ser\u00e3o embalados com rede de pl\u00e1stico para proteger a pintura. Os cilindros podem ser entregues em paletes ou a granel num contentor.<\/p>\n<p>Os cilindros s\u00e3o acompanhados de um relat\u00f3rio de ensaio detalhado, incluindo o relat\u00f3rio de ensaio de f\u00e1brica, o relat\u00f3rio de ensaio hidr\u00e1ulico e o relat\u00f3rio de ensaio da T\u00dcV para a homologa\u00e7\u00e3o TPED, etc.<br \/>\nRelat\u00f3rio de refer\u00eancia:<br \/>\nEnvie um e-mail para sales@sinocleansky.com para obter um modelo mais detalhado do relat\u00f3rio de ensaio.<\/p>","protected":false},"featured_media":20833,"parent":0,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[]},"application":[],"category-type":[780],"capacity":[742],"certifications":[775,777],"energy":[],"medium-industrial-gas":[845,846,848,849,850,853,855],"industrial-gas-equipment":[],"inspection-agency":[842],"material":[769],"product-category":[727],"products":[710,807],"related-products-group":[],"working-pressure-range":[838],"class_list":["post-3603","product","type-product","status-publish","has-post-thumbnail","hentry","category-type-products","capacity-40l-200l","certifications-iso","certifications-tped-ped","medium-industrial-gas-argon-ar","medium-industrial-gas-nitrogen-n2","medium-industrial-gas-hydrogen-h2","medium-industrial-gas-helium-he","medium-industrial-gas-oxygen-o2","medium-industrial-gas-nitrous-oxide-n2o","medium-industrial-gas-carbon-dioxide-co2","inspection-agency-tuv","material-steel","product-category-high-pressure-series","products-gas-cylinders","products-seamless-steel-gas-cylinders","working-pressure-range-high-pressure-20-30-mpa"],"acf":{"description_summary":"<ul>\r\n \t<li><strong>EN ISO 9809 standard<\/strong> \u2014 manufactured to the European high-pressure cylinder standard (Part 1: quenched &amp; tempered; Part 3: normalized).<\/li>\r\n \t<li><strong>TPED approved, with \u03c0 (pi) mark<\/strong> \u2014 compliant for the EU market.<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li><strong>\u00a0T\u00dcV certified<\/strong> \u2014 verified by T\u00dcV or other international inspection authority.<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li><strong>High working pressure up to 30 MPa (300 bar)<\/strong> \u2014 super-high pressure options available.<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li><strong>Broad gas compatibility<\/strong> \u2014 oxygen, nitrogen, argon, CO\u2082, hydrogen, and more.<\/li>\r\n \t<li><strong>Dual manufacturing processes<\/strong> \u2014 both pipe-spun and billet-pierced cylinders available.<\/li>\r\n<\/ul>","image_gallery":[20833,20834,20835,20836,20853,20854],"description":"<ul>\r\n \t<li>SinoCleansky EN ISO 9809 gas cylinders are manufactured strictly in accordance with the EN ISO 9809 standard series \u2014 including both Part 1 (quenched &amp; tempered steel) and Part 3 (normalized steel) \u2014 with TPED approval and the \u03c0 (pi) mark on every cylinder.<\/li>\r\n \t<li>Each cylinder comes with LRS or other international third-party inspection reports.<\/li>\r\n \t<li>As a high-end product line, these cylinders are widely used in the European market and meet higher performance requirements.<\/li>\r\n \t<li>Our EN ISO 9809 cylinders are available as both pipe-spun and billet-pierced types, serving a broad range of gases including Oxygen (O\u2082), Nitrogen (N\u2082), Argon (Ar), Carbon Dioxide (CO\u2082), Helium (He), Nitrous Oxide (N\u2082O), and Hydrogen (H\u2082), across industrial, fire-fighting, energy, medical, urban infrastructure, and other sectors.<\/li>\r\n<\/ul>","description_image_paths":"","description_image_gallery":[{"description_image_gallery_list":20839},{"description_image_gallery_list":20840},{"description_image_gallery_list":20841},{"description_image_gallery_list":20829},{"description_image_gallery_list":20831},{"description_image_gallery_list":20842}],"technical_specifications":"<strong>Popular EN ISO9809-1 Cylinder (TPED)<\/strong>\r\n<table class=\"aligncenter\" style=\"height: 672px; width: 100%; border-collapse: collapse;\" border=\"5\">\r\n<tbody>\r\n<tr style=\"height: 48px;\">\r\n<td style=\"width: 19.9681%; height: 48px;\" width=\"124\"><strong>Model<\/strong><\/td>\r\n<td style=\"width: 19.9681%; height: 48px;\" width=\"157\"><strong>Standard<\/strong><\/td>\r\n<td style=\"width: 19.9681%; height: 48px;\" width=\"141\"><strong>Out Diameter (mm)<\/strong><\/td>\r\n<td style=\"width: 19.9681%; height: 48px;\" width=\"155\"><strong>Water Capacity (L)<\/strong><\/td>\r\n<td style=\"width: 19.9681%; height: 48px;\" width=\"179\"><strong>Working Pressure (bar)<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\" width=\"124\">OD140-20-5L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\" width=\"157\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\" width=\"141\">140<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\" width=\"155\">5<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\" width=\"179\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD140-20-7L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">140<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">7<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD140-20-10L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">140<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">10<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD159-20-14L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">159<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">14<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD165-20-14L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">165<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">14<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD203-20-20L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">203<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">20<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD232-20-40L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">232<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">40<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD232-H2-20-40L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">232-H2<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">40<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD232-20-43.7L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">232<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">43.7<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD232-15-47L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">232<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">47<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD232-20-47L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">232<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">47<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD232-15-50L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">232<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">50<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD232-20-50L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">232<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">50<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD267-15-68L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">267<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">68<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD267-20-68L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">267<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">68<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD267-30-80L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">267<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">80<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">300<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD356-20-140L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">356<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">140<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD356-20-150L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">356<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">150<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">200<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%; text-align: center;\">OD406-25-190L<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">EN ISO 9809-1<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">406<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">190<\/td>\r\n<td style=\"width: 19.9681%; text-align: center;\">250<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>Popular EN ISO9809-3 Cylinder (TPED)<\/strong>\r\n<table class=\"aligncenter\" style=\"width: 100%; border-collapse: collapse;\" border=\"5\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 19.9681%;\" width=\"124\"><strong>Model<\/strong><\/td>\r\n<td style=\"width: 19.9681%;\" width=\"157\"><strong>Standard<\/strong><\/td>\r\n<td style=\"width: 19.9681%;\" width=\"141\"><strong>Out Diameter (mm)<\/strong><\/td>\r\n<td style=\"width: 19.9681%;\" width=\"155\"><strong>Water Capacity (L)<\/strong><\/td>\r\n<td style=\"width: 19.9681%;\" width=\"179\"><strong>Working Pressure (bar)<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\" width=\"124\">OD-108-15-2L<\/td>\r\n<td style=\"width: 19.9681%;\" width=\"157\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\" width=\"141\">108<\/td>\r\n<td style=\"width: 19.9681%;\" width=\"155\">2<\/td>\r\n<td style=\"width: 19.9681%;\" width=\"179\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\">OD-108-15-3L<\/td>\r\n<td style=\"width: 19.9681%;\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\">108<\/td>\r\n<td style=\"width: 19.9681%;\">3<\/td>\r\n<td style=\"width: 19.9681%;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\">OD-140-15-5L<\/td>\r\n<td style=\"width: 19.9681%;\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\">140<\/td>\r\n<td style=\"width: 19.9681%;\">5<\/td>\r\n<td style=\"width: 19.9681%;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\">OD-140-15-10L<\/td>\r\n<td style=\"width: 19.9681%;\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\">140<\/td>\r\n<td style=\"width: 19.9681%;\">10<\/td>\r\n<td style=\"width: 19.9681%;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\">OD-159-15-14L<\/td>\r\n<td style=\"width: 19.9681%;\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\">159<\/td>\r\n<td style=\"width: 19.9681%;\">14<\/td>\r\n<td style=\"width: 19.9681%;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\">OD-180-15-20L<\/td>\r\n<td style=\"width: 19.9681%;\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\">180<\/td>\r\n<td style=\"width: 19.9681%;\">20<\/td>\r\n<td style=\"width: 19.9681%;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\">OD-219-15-20L<\/td>\r\n<td style=\"width: 19.9681%;\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\">219<\/td>\r\n<td style=\"width: 19.9681%;\">20<\/td>\r\n<td style=\"width: 19.9681%;\">150<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 19.9681%;\">OD-219-15-40L<\/td>\r\n<td style=\"width: 19.9681%;\">EN ISO 9809-3<\/td>\r\n<td style=\"width: 19.9681%;\">219<\/td>\r\n<td style=\"width: 19.9681%;\">40<\/td>\r\n<td style=\"width: 19.9681%;\">150<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>","packaging_shipping":"All cylinders are wrapped in protective plastic netting to safeguard the painted finish. For small steel cylinders, we typically recommend individual carton boxing; the cylinders can then be shipped on pallets or loose-loaded in the container.","packaging_image_paths":"","packaging_image_gallery":[{"packaging_image_gallery_list":20843},{"packaging_image_gallery_list":20845},{"packaging_image_gallery_list":20850}],"report_certifications_content":"Cylinders are with detailed test report, including the factory test report, hydraulic test report and TUV test report for TPED approval, etc.Reference Report:E-mail sales@sinocleansky.com to get more detailed test report specimen.","report_certifications_image":[{"report_certifications_image-certification_image":3595},{"report_certifications_image-certification_image":3599}],"faq":[{"faq_-_question":"What is the difference between EN ISO 9809-1 and 9809-3?","faq_-_answer":"ISO 9809-1 uses quenched & tempered steel with a tensile strength up to 1100 MPa, supporting working pressures up to 200 bar (20 MPa) or higher. ISO 9809-3 uses normalized steel with a tensile strength up to 800 MPa, typically rated at 150 bar (15 MPa). Part 1 is for high-pressure industrial applications; Part 3 offers a cost-effective option for standard-pressure use."},{"faq_-_question":"What certifications does this cylinder carry?","faq_-_answer":"Every cylinder is manufactured to EN ISO 9809-1 or 9809-3, TPED-approved with the \u03c0 mark, and backed by LRS or other international third-party inspection reports."},{"faq_-_question":"Do you offer hydrogen-compatible cylinders?","faq_-_answer":"Yes. We supply dedicated hydrogen cylinders (e.g., 232-40L at 200 bar with 5.8 mm wall thickness) designed specifically for H\u2082 service."}],"specification_image_paths":"","pdf_file_paths":[{"pdf_files_name":"En Iso9809 Cylinder Tped Download 01","pdf_files_-_pdf_file":3600,"pdf_page_image_paths":[3601,3602]}],"video_links":null,"type":"EN ISO9809 Cylinder (TPED)","material":"Steel","working_pressure":"30Mpa","capacity":"5L-80L","medium":"Argon, Carbon Dioxide, Nitrous Oxide, Oxygen, Nitrogen, Hydrogen, Helium","standards_certifications":"ISO9809, TPED, TUV","application_scenario":"Energy \/ Industrial \/ Firefighting \/ Medical \/ Welding & Cutting \/ Others"},"_links":{"self":[{"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/product\/3603","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media\/20854"},{"embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media\/20853"},{"embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media\/20836"},{"embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media\/20835"},{"embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media\/20834"},{"embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media\/20833"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media\/20833"}],"wp:attachment":[{"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/media?parent=3603"}],"wp:term":[{"taxonomy":"application","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/application?post=3603"},{"taxonomy":"category-type","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/category-type?post=3603"},{"taxonomy":"capacity","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/capacity?post=3603"},{"taxonomy":"certifications","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/certifications?post=3603"},{"taxonomy":"energy","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/energy?post=3603"},{"taxonomy":"medium-industrial-gas","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/medium-industrial-gas?post=3603"},{"taxonomy":"industrial-gas-equipment","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/industrial-gas-equipment?post=3603"},{"taxonomy":"inspection-agency","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/inspection-agency?post=3603"},{"taxonomy":"material","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/material?post=3603"},{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/product-category?post=3603"},{"taxonomy":"products","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/products?post=3603"},{"taxonomy":"related-products-group","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/related-products-group?post=3603"},{"taxonomy":"working-pressure-range","embeddable":true,"href":"https:\/\/www.sinocleansky.com\/pt\/wp-json\/wp\/v2\/working-pressure-range?post=3603"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}